SubConn Penetrator – Water Blocked Right Angle

SubConn Penetrator - Water Blocked Right Angle

Drawing information

Dimensions in mm (1 mm = 0.03937 inch)
Threads in inches (1 inch = 25.4 mm)

Connector specifications

  • Voltage rating (all penetrators): 300/600 V DC/AC rms (depends on cable)
  • Current rating: Depends on wire and conductor size
  • Insulation resistance: > 200 Mohm
  • Temperature rating (water): – 4 to 60˚C, – 25 to 140˚F
  • Temperature rating (air): – 40 to 60˚C, – 40 to 140˚F
  • Storage temperature rating: – 40 to 60˚C, – 40 to 140˚F
  • Qualified pressure tested: 800 bar, 11,600 psi

Material specifications

  • Penetrator body: Chloroprene rubber
  • Penetrator metal part: Brass, stainless steel
  • Wire and conductor size: 18 AWG, 0.82 mm2 to 22 AWG, 0.33 mm2 (depends on wire quantity)
  • Penetrator wire leads (30 cm, 1 ft): PTFE
  • Cable outside diameter: Depends on penetrator and cable type
  • O-rings: Nitrile
  • Inline cable length: Customer specified
  • Inline cable type: Customer specified (SubConn® cables only)

Inline cable color code

  • Depends on the corresponding SubConn® connector and cable type.