Coax hybrid cable – Type 6926KCC
1 x Coaxial cable | D0624 0.14 mm² (7/0.16 mm) Tinned Copper Polyolefin Dielectric at 2.10 mm Tinned Copper Secondary Conductor HDPE Jacket to 3.30 mm LLDPE Jacketed, 1.20 mm nom RTI OD: 5.70 mm Colour: NAT |
1 x Twisted quad | 0.22 mm² (7/0.20 mm) Tinned Copper XLPE Insulated to 0.90 mm 4 off these and twisted around central filler with Tinned Copper drain wire Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50% Overall helical PET isolation tape, minimum overlap 50% OD: 2.40 mm Colour: WH RD BU GN |
8 x Conductors | 1.00 mm² (32/0.20 mm) Tinned Copper XLPE Insulated, 0.55 mm nom RTI OD: 2.40 mm Colour: GN BU RD WH BN OR GY YW |
1 x Twisted quint | 0.14 mm² (7/0.16 mm) Tinned Copper XLPE Insulated to 0.80 mm 5 off these and twisted around central filler with Tinned Copper drain wire Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50% Overall helical PET isolation tape, minimum overlap 50% OD: 2.40 mm Colour: WH YW RD BU GN |
Lay up | Twisted quad, twisted quint and conductors are twisted around the coaxial cable with Non-woven Polyester Tissue tape, minimum overlap 50% OD: 10.40 mm |
Strength member | Vectran® fibre braid, 24/2/1 /1,666 dTex 58 mm pitch OD: 11.40 mm |
Jacket | Polyether Polyurethane, 85 Shore A, Halogen Free, 1.45 mm nom RTI OD: 14.00 mm +/-0.50 Colour: RD |
Max. operating temp Static Dynamic |
+90°C +80°C |
Cold flex temp | -20°C |
Min. break load | 7 kN |
Depth rating | 5,000 m |
Min. recommended bend radius Static Dynamic |
116 mm 216 mm |
Nominal weight In air In seawater |
241 kg/km 74 kg/km at SG 1.025 |
D0624 coaxial cable Conductor resistance Characteristic impedance Capacitance |
130 Ω/km at 20°C 75 Ω 55 pF/m |
Attenuation at 1 MHz 2 MHz 5 MHz 10 MHz 20 MHz 50 MHz |
1.60 dB/100 m Nom 2.30 dB/100 m Nom 3.60 dB/100 m Nom 5.10 dB/100 m Nom 7.20 dB/100 m Nom 11.50 dB/100 m Nom |
1 mm² conductors Max. conductor resistance Voltage rating |
19.20 Ω/km at 20°C 600 V |
0.22 mm² conductors Max. conductor resistance Voltage rating |
88.20 Ω/km at 20°C 24 V |
0.14 mm² conductors Max. conductor resistance Voltage rating |
137.80 Ω/km at 20°C 24 V |
Min. insulation resistance Core – Core Core – Screen |
> 1.00 GΩ/km > 500 MΩ/km |
In compliance with | CE, UK CA, UK NI, RoHS, LVD |