Data cable – Type 4022

Data cable - Type 4022

Construction characteristics

Shielded twisted pair: 0,50 mm² bare copper conductor IEC 60228
class 5 insulated with HDPE
Nominal wall thickness 0,43 mm, nominal diameter 1,75 mm
2 conductors twisted together white-blue with a polyester tape, tinned copper drain wire
7 x 0,3 mm and aluminium/polyester tape,
Polyethylene sheath nominal wall thickness 0,30 mm, nominal diameter 4,35 mm
Colour white numbered 1-11 (11 ea)

Fillers: 2 ea

Filling compound: Silicone water blocking compound

Outer jacket: Hydrolysis UV resistant Polyurethane. Nominal wall thickness 1,55 mm, black

Mechanical characteristics

Diameter: 21,20 mm

Weight in air: 549 kg/km

Weight in seawater: 187 kg/km

Weight in fresh water: 196 kg/km

Min. bending radius, static: 106 mm static

Min. bending radius, dynamic: 212 mm

Operating temperature: -30°C – +80°C

Electrical characteristics

Conductor resistance: < 39,00 Ω/km @ 20°C for 0,50 mm² conductors Operating voltage: 600 V for 0,50 mm² conductors

Related files

Data cable – Type 4022

Call us

(858) 454-4044