Power & data cable – Type 4622CC
2 x Conductors | 1.00 mm2 (32/0.20 mm) Tinned Copper XLPE insulated, 0.45 mm nom RTI OD: 2.20 mm Colour: BU BK |
5 x Screened twisted pairs | 0.22 mm² (7/0.20 mm) Tinned Copper XLPE insulated to 1.00 mm 2 off twisted together with Tinned Copper drain wire and filler in interstices Overall helical 12/23μm Ali/PET foil screen, minimum overlap 50% Overall helical PET isolation tape, minimum overlap 50% OD: 2.20 mm Colour: BU/WH BK/WH YW/WH GN/WH OR/WH |
1 x Jacketed screened twisted pairs |
0.22 mm² (7/0.20 mm) Tinned Copper XLPE insulated to 1.00 mm 2 off twisted together with Tinned Copper drain wire and filler in interstices Overall helical 12/23μm Ali/PET foil screen, minimum overlap 50% Overall helical PET separation tape, minimum overlap 50% LLD PE jacketed, 0.40mm nom RTI OD: 3.00 mm Colour: RD/WH BK |
Lay up | The conductors and screened twisted pairs are twisted around the jacketed screen twisted pair. Overall helical PET binding tape, minimum overlap 50% OD: 7.5 mm |
Overall screen | 0.20 mm Tinned Copper Braid Minimum optical coverage 85% Overall helical PET separation tape minimum overlap 50% OD: 8.40 mm |
Jacket | Polyether Polyurethane 85 Shore A Halogen Free 1.80 mm nom RTI OD: 12.00 mm +/- 0.40 Colour: BU |
Max. operating temp Static Dynamic |
+90°C +80°C |
Cold flex temp | -40°C |
Depth rating | 3,000 m |
Min. recommended bend radius Static Dynamic |
80 mm 120 mm |
Nominal weight In air In seawater |
204 kg/km 88 kg/km at SG 1.025 |
1.00 mm² conductors Max. conductor resistance Voltage rating Test voltage |
19.20 Ω/km at 20°C 600 V DC 3,000 V DC for 1 min |
0.22 mm² conductors Conductor resistance voltage Voltage rating Test voltage Capacitance Impedance Attenuation 1 MHz 10 MHz |
88.20 Ω/km at 20°C 24 V DC 1,500 V DC for 1 min 85 pF/m 60 ±5 Ω at 1-10 MHz 10.0 dB/100 m 25.0 dB/100 m |
Min. insulation resistance Core – Core Core – Screen Screen – Screen |
> 100 GΩ/km > 50 MΩ/km > 10 MΩ/km |
In compliance with | CE, UK CA, UK NI, RoHS, LVD |