Power/signal cable – Type 2019/B

Power/signal cable - Type 2019/B

Construction characteristics

Power conductors 2.00 mm² bare copper conductor insulated with PVC (2 each)

Shielded twisted pair 0.22 mm² bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil. (2 each)

Inner jacket PVC jacket

Inner jacket Polyurethane jacket

Strength member Braided Kevlar

Outer jacket Polyurethane jacket. Colour blue

Mechanical characteristics

Diameter 14.30 mm ±0.30 mm

Weight in air 220 kg/km nom

Weight in seawater 55 kg/km nom

Min. breaking strength 1,500 kg

Min. bending radius, static 1A60 mm

Min. bending radius, dynamic 210 mm

Depth rating 5,000 m

Operating temperature range -20̊ C to 80̊ C

Electrical characteristics

Operating voltage 600 V for 2.00 mm² conductors
24 V for 0.22 mm² conductors

Test voltage 3,000 V DC for 1 min. for 2.00 mm² conductors (cond. – cond.)
1,500 V DC for 1 min. for 0.22 mm² conductors (cond. – cond.)

Conductor resistance ≤ 10.0 ohm/km for 2.00 mm² conductors
≤ 96.2 ohm/km for 0.22 mm² conductors

Insulation resistance ≥ 100 Mohm×km for 2.00 mm² conductors
≥ 5,000 Mohm×km for 0.22 mm² conductors

Capacitance 70 pF/m for 0.22 mm² pair

Characteristic impedance 60 ±5 Ohm for 0.22 mm² pair

Attenuation 10.0 dB/100 m at 1 MHz
25.0 dB/100 m at 10 MHz

Related files

Power/signal cable – Type 2019 B

Call us

(858) 454-4044

Address

7416 Cabrillo Avenue, La Jolla, CA  92037, United States