Coax: 75 ohm coax (1 each)
Conductor: 1.34 mm² bare copper conductor insulated with PE (1 each)
Shielded twisted pair: 0.50 mm² bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 each)
Shielded twisted pair: 1.34 mm² bare copper conductor insulated with PE. Two conductors twisted together with a tinned copper drain wire and aluminium/polyester foil (1 each)
Twisted pair: 0.22 mm² tinned copper conductor insulated with PE. Two conductors twisted together (1 each)
Filling compound: The cable is filled with cable filling compound
Shield: Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket: Polyurethane jacket. Colour orange
Diameter: 11.00 mm ±0.50 mm
Weight in air: 165 kg/km nom
Weight in seawater: 70 kg/km nom
Min. bending radius, static: 100 mm
Min. bending radius, dynamic: 145 mm
Depth rating: 5,000 m
Operating voltage: 600 V for 1.34 mm² and 0.50 mm² conductors
24 V for 0.22 mm² conductors
Conductor resistance: ≤ 135.0 ohm/km for coax
≤ 15.3 ohm/km for 1.34 mm² conductors
≤ 41.0 ohm/km for 0.50 mm² conductors
≤ 96.2 ohm/km for 0.22 mm² conductors
Insulation resistance: ≥ 5000 Mohm×km for coax, 1.34 mm² and 0.22 mm² conductor
≥ 10000 Mohm×km for 1.34 mm² and 0.50 mm² conductors (cond. – cond.)
≥ 100 Mohm×100 m for 1.34 mm² and 0.50 mm² conductors (cond. – shield)
Capacitance: 59 pF/m for coax
155 pF/m for 1.34 mm² pair
107 pF/m for 0.50 mm² pair
57 pF/km for 0.22 mm² pair
Impedance: 37 ±5 Ohm at 1-10 MHz for 1.34 mm² pair
52 ±5 Ohm at 1-10 MHz for 0.50 mm² pair
73 ±5 Ohm at 1-10 MHz for 0.22 mm² pair
Attenuation: 7.0 dB/100 m at 1 MHz for 1.34 mm², 0.50 mm² and 0.22 mm² pair
17.5 dB/100 m at 10 MHz for 1.34 mm² pair