Power/signal cable – Type 5071
| Conductor | 0.50 mm² bare copper conductor insulated with PE (7 each) |
| Shield | Tinned copper braid, coverage 85% |
| Tape | Fleece tape |
| Outer jacket | Polyurethane jacket. Colour black |
| Strength member | Aramid yarn (1 each) |
| Flame retardant | Acc. to IEC 60332-1 |
| Halogen free | Acc. to IEC 60754 |
| Diameter | 10.00 mm ±0.30 mm |
| Weight in air | 140 kg/km nom |
| Weight in seawater | 60 kg/km nom |
| Min. bending radius, static | 70 mm |
| Min. bending radius, dynamic | 100 mm |
| Min. breaking strength | 36 kN |
| Depth rating | 3,000 m |
| Operating temperature range | -20°C – +80°C |
| Operating voltage | 750 V DC |
| Test voltage | 3,000 V DC for 1 min |
| Conductor resistance | ≤ 41.0 Ω/km |
| Insulation resistance | ≥ 10,000 MΩ×km (cond – cond) ≥ 100 MΩ×100 m (cond – shield) ≥ 10 MΩ/km (shield – shield) |