Power/signal cable – Type 5071/B
| Conductor | 7 x 0.50 mm² bare copper conductor insulated with XLPE compound (IEC 60228 Class 5). Elements stranded together with Hot Melt Jelly Filler |
| Shield | Tinned copper braid, coverage 85% |
| Tape | Non-woven binder tape |
| Outer jacket | UV resistant polyurethane jacket. Colour black |
| Strength member | Aramid yarn (1 each) |
| Flame retardant | Acc. to CEI EN 60332-1-2, IEC 60332-1-2:2004:07, EN 60332-1-2:2004-11 |
| Halogen free | Acc. to IEC 60754-2, CEI 20-37/2-2, EN 50267-2-2 |
| Diameter | 10.10 mm ±0.30 mm |
| Weight in air | 147 kg/km nom |
| Weight in seawater | 65 kg/km nom |
| Min. bending radius, static | 70 mm |
| Min. bending radius, dynamic | 100 mm |
| Min. breaking strength | 3.6 kN |
| Depth rating | 3,000 m |
| Operating temperature range | -20°C – +80°C |
| Operating voltage | 750 V DC |
| Test voltage | 3,000 V DC for 1 min |
| Conductor resistance | ≤ 39.0 Ω/km |
| Insulation resistance | ≥ 1 GΩ×km (cond – cond) |