Follow these instructions carefully to ensure correct use of your SubConn® connectors.
Handling
Always apply grease before mating
Disconnect by pulling straight, not at an angle
Do not pull on the cable and avoid sharp bends at cable entry
When using a bulkhead connector, ensure that there are no angular loads
Make sure to apply the recommended torque when tightening bulkhead nuts (see page 117)
SubConn® connectors should not be exposed to extended periods of heat or direct sunlight. If a connector becomes very dry, it should be soaked in fresh water before use
Greasing products
Greasing and mating above water (dry mate)
Connectors must be greased with Molykote 44 Medium before every mating
A layer of grease corresponding to minimum 1/10 of socket depth should be applied to the female connector
The inner edge of all sockets should be completely covered, and a thin transparent layer of grease left visible on the face of the connector
After greasing, fully mate the male and female connector in order to secure optimal distribution of grease on pins and in sockets
To confirm that grease has been sufficiently applied, de-mate and check for grease on every male pin. Then re-mate the connector
Greasing and mating under water (wet mate)
Connectors must be greased with Molykote 44 Medium before every mating
A layer of grease corresponding to approximately 1/3 of socket depth should be applied to the female connector
All sockets should be completely sealed, and a transparent layer of grease left visible on the face of the connector
After greasing, fully mate the male and female connector and remove any excess grease from the connector joint
Cleaning
Cleaning products
*General cleaning and removal of any accumulated sand or mud on a connector should be performed using spray based contact cleaner (isopropyl alcohol)
New grease must be applied again prior to mating
Always use Loctite 5910 to lock non-metallic (PEEK) connectors
For locking metallic connectors, the use of Loctite 243 is recommended
Molykote 44
MacArtney offers Molykote 44 Medium in two sizes (10 ml and 100 ml), connectors must be greased with Molykote 44 Medium before every mating.