Data cable – Type 4022

Data cable - Type 4022

Data cable – Type 4022

Construction characteristics

Shielded twisted pair 0.50 mm² bare copper conductor IEC 60228 class 5 insulated with HDPE
Nominal wall thickness 0.43 mm, nominal diameter 1.75 mm
2 conductors (white-blue) twisted together with a polyester tape, tinned copper
drain wire 7 x 0.3 mm and aluminium/polyester tape
Polyethylene sheath nominal wall thickness 0.30 mm, nominal diameter 4.35 mm
Colour white numbered 1-11 (11 each)
Filler 2 each
Filling compound Silicone water blocking compound
Outer jacket Hydrolysis UV resistant polyurethane jacket. Nominal wall thickness 1.55 mm
Colour black

Mechanical characteristics

Diameter 21.20 mm ± 0.60 mm
Weight in air 507 kg/km
Weight in seawater 145 kg/km nom
Weight in fresh water 154 kg/km nom
Min. bending radius, static 106 mm
Min. bending radius, dynamic 212 mm
Operating temperature range -30°C – +80°C

Electrical characteristics

Conductor resistance < 39.0 Ω/km at 20°C for 0.50 mm² conductor
Operating voltage 600 V for 0.50 mm² conductor
Test voltage 3,500 Vac (cond – cond)
3,500 Vac (cond – shield)
Capacitance (calculated) 75 ±5 pF/m
Impendance (calculated) 72 ±5 Ω
Attenuation (calculated) < 28 dB/km at 1 MHz

Call us

(858) 454-4044

Address