4 x Screened twisted pairs | 1.00 mm² (32/0.20 mm) Tinned Copper XLPE insulated to 2.20 mm 2 off these and twisted together with 0.22 mm² (7/0.20 mm) Tinned Copper drain wire in interstice Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50% Overall helical PET isolation tape, minimum overlap 50% OD: 4.60 mm Colour: WH/RD BU/RD BU/GN RD/GN |
Lay up and overall screen | The 4 screened twisted pairs are twisted around the central filler Overall water-swellable tape, minimum overlap 50% Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50% with 0.50 mm² (16/0.20 mm) Tinned Copper drain wire pulled under OD: 10.70 mm |
Jacket | Polyether Polyurethane, 85 Shore A, Halogen Free, 1.80 mm nom RTI OD: 14.30 mm +/-0.30 Colour: BK |
Max. operating temp Static Dynamic |
+90°C +80°C |
Cold flex temp | -40°C |
Depth rating | 3,000 m |
Min. recommended bend radius Static Dynamic |
90 mm 150 mm |
Nominal weight In air In seawater |
218 kg/km 53 kg/km at SG 1.025 |
1.00 mm2 conductors Max. conductor resistance Voltage rating Test voltage Capacitance Impedance Inductance |
19.20 Ω/km at 20°C 1,000 V DC 4,000 V DC for 1 minute 110 pF/m nom 50 +/- 5 Ω at 1 – 1 o MHz 240 µH/m |
Attenuation at 1 MHz 10 MHz |
3.90 dB/100 m 12.50 dB/100 m |
Min. insulation resistance Core – Core Core – Screen |
> 1.00 GΩ/km > 500 MΩ/km |
In compliance with | CE, UK CA, UK NI, RoHS, LVD |