Power & data cable – Type 2019KCC

Power & data cable - Type 2019KCC

Power & data cable – Type 2019KCC

Construction characteristics

2 x Screened twisted pairs 0.22 mm² (7/0.20 mm) Tinned Copper Polyolefin insulated to 1.15 mm
2 off twisted with Tinned Copper drain wire in interstice
Overall helical 12/23μm Ali/PET foil screen, minimum overlap 50%
OD: 2.5 mm
Colour: YW/GY GN/WH
2 x Conductors 2.00 mm² (63/0.20 mm) Tinned Copper HDPE insulated, 0.80 mm nom RTI
OD: 3.0 mm
Colour: BN BU
Lay up Conductors and twisted pairs twisted together with fillers in interstices
OD: 6.00 mm
Encapsulation PVC 0.50 mm nom RTI
OD: 7.00 mm
Colour: WH
Bedding Polyether Polyurethane 85 Shore A Halogen Free 1.00 mm nom RTI
OD: 9.00 mm
Colour: BU
Strength member Vectran® fibre braid 24/2/1/1666 dTex
OD: 10.00 mm
Jacket Polyether Polyurethane 85 Shore A Halogen Free 2.15 mm nom RTI
OD: 14.30 mm +/- 0.30
Colour: BU

Mechanical characteristics

Max. operating temp +80°C
Cold flex temp -20°C
Min. break load 15 kN
Recommended safe workload 3 kN
Depth rating 5,000 m

Mechanical characteristics

Min. recommended bend radius
Static
Dynamic
 
115 mm
215 mm
Nominal weight
In Air
In seawater
 
218 kg/km
54 kg/km at SG 1.025

Electrical characteristics

0.22 mm² conductors
Max. conductor resistance
 
Max. recommended voltage
 
Calculated characteristic
impedance
 
Calculated capacitance
 
Test voltage
 
96.20 Ω/km at 20°C
 
24 V
 
88 Ω
 
 
75 pF/m
 
1,500 V DC for 1 min
2.00 mm² Conductors
Maximum conductor resistance
 
Max. recommended voltage
 
Max. recommended
current/conductor
 
Test Voltage
 
10.00 Ω/KM at 20°C
 
600 V
 
16 A
 
 
3,000 V DC for 1 minute
Min. insulation resistance
Core – Core
Core – Screen
 
> 500 MΩ/km at 250V
> 250 MΩ/km at 250V
In compliance with CE, UK CA, UK NI, RoHS, LVD