Power & data cable – Type 2019KCC
2 x Screened twisted pairs | 0.22 mm² (7/0.20 mm) Tinned Copper Polyolefin insulated to 1.15 mm 2 off twisted with Tinned Copper drain wire in interstice Overall helical 12/23μm Ali/PET foil screen, minimum overlap 50% OD: 2.5 mm Colour: YW/GY GN/WH |
2 x Conductors | 2.00 mm² (63/0.20 mm) Tinned Copper HDPE insulated, 0.80 mm nom RTI OD: 3.0 mm Colour: BN BU |
Lay up | Conductors and twisted pairs twisted together with fillers in interstices OD: 6.00 mm |
Encapsulation | PVC 0.50 mm nom RTI OD: 7.00 mm Colour: WH |
Bedding | Polyether Polyurethane 85 Shore A Halogen Free 1.00 mm nom RTI OD: 9.00 mm Colour: BU |
Strength member | Vectran® fibre braid 24/2/1/1666 dTex OD: 10.00 mm |
Jacket | Polyether Polyurethane 85 Shore A Halogen Free 2.15 mm nom RTI OD: 14.30 mm +/- 0.30 Colour: BU |
Max. operating temp | +80°C |
Cold flex temp | -20°C |
Min. break load | 15 kN |
Recommended safe workload | 3 kN |
Depth rating | 5,000 m |
Min. recommended bend radius Static Dynamic |
115 mm 215 mm |
Nominal weight In Air In seawater |
218 kg/km 54 kg/km at SG 1.025 |
0.22 mm² conductors Max. conductor resistance Max. recommended voltage Calculated characteristic impedance Calculated capacitance Test voltage |
96.20 Ω/km at 20°C 24 V 88 Ω 75 pF/m 1,500 V DC for 1 min |
2.00 mm² Conductors Maximum conductor resistance Max. recommended voltage Max. recommended current/conductor Test Voltage |
10.00 Ω/KM at 20°C 600 V 16 A 3,000 V DC for 1 minute |
Min. insulation resistance Core – Core Core – Screen |
> 500 MΩ/km at 250V > 250 MΩ/km at 250V |
In compliance with | CE, UK CA, UK NI, RoHS, LVD |