Power & data cable – Type 4026

Power & data cable - Type 4026

Power & data cable – Type 4026

Construction characteristics

Conductor (center) 1.50 mm² bare copper conductor IEC 60228 class 5 insulated with HDPE
Nominal wall thickness 0.70 mm, nominal diameter 2.95 mm
Colours blue, red, yellow, white (4 each)
Shielded twisted pair 0.50 mm² bare copper conductor IEC 60228 class 5 insulated with HDPE
Nominal wall thickness 0.43 mm, nominal diameter 1.75 mm
2 conductors twisted together white-blue with a polyester tape, tinned copper
drain wire 7 x 0.3 and aluminium/polyester tape
Polyethylene sheath, nominal thickness 0.30 mm, nominal diameter 4.35 mm
Colour white numbered 1-11, (11 each)
Tape Protective polyester
Inner sheath SEBS TPR, nominal wall thickness 2.10 mm, nominal diameter 11.35 mm
Filling compound Silicone water blocking compound
Outer jacket Hydrolysis UV resistant Polyurethane, nominal wall thickness 1.70 mm
Colour black

Mechanical characteristics

Diameter 23.50 mm ± 0.60 mm
Weight in air 647 kg/km
Weight in seawater 202 kg/km
Weight in fresh water 214 kg/km
Min. bending radius, static 118 mm
Min bending radius, dynamic 235 mm
Qualified pressure test 6,000 m (600 bar)
Operating temperature range -30°C – +80°C

Electrical characteristics

Operating voltage 600 V for 0.50 mm² conductor
1,000 V for 1.50 mm² conductor
Conductor resistance < 39.00 Ω/km at 20°C for 0.50 mm² conductor
< 13.30 Ω/km at 20°C for 1.50 mm² conductor
Test voltage 3,500 Vac for 0.50 mm² conductor (cond – cond)
3,500 Vac for 0.50 mm² conductor (cond – shield)
4,000 Vac for 1.50 mm² conductor (cond – cond)
4,000 Vac for 1.50 mm² conductor (cond – shield)
Capacitance (calculated) 75 ±5 pF/m
Impedance (calculated) 72 ±5 Ω
Attenuation (calculated) < 28 dB/km at 1 MHz