Power & data cable – Type 4591CC

Power & data cable - Type 4591CC

Power & data cable – Type 4591CC

Construction characteristics

8 x Screened twisted pairs 0.50 mm² (16/0.20 mm) Tinned Copper XLPE insulated to 1.50 mm
2 off twisted together with Tinned Copper drain wire and filler in interstices
Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50%
Overall minimum helical overlap PET 50% isolation tape, minimum overlap 50%
OD: 3.20 mm
Colour: WH/YW WH/GN WH/BU WH/RD RD/YW RD/GN RD/BU GN/BU
1 x Screened twisted triad 1.50 mm² (30/0.25 mm) Tinned Copper XLPE Insulated to 2.50 mm
3 off twisted together with Tinned Copper drain wire and fillers in interstices
Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50%
Overall helical PET isolation tape, minimum overlap 50%
OD: 5.60 mm
Colour: BU WH RD
Lay up The screened twisted pairs are twisted around the screened triad
Overall water-swellable tape, minimum overlap 50%
OD: 12.80 mm
Jacket Polyether Polyurethane 85 Shore A, Halogen Free 1.80 mm nom RTI
OD: 16.40 mm +/- 0.50
Colour: BK

Mechanical characteristics

Max. operating temp
Static
Dynamic
 
+90°C
+80°C
Cold flex temp -40°C
Depth rating 5,000 m
Min. recommended bend radius
Static
Dynamic
 
118 mm
169 mm
Nominal weight
In air
In seawater
 
334 kg/km
104 kg/km at SG 1.025

Electrical characteristics

1.50 mm² Conductors
Max. conductor resistance
 
Voltage rating
 
Test voltage
 
13.20 Ω/km at 20°C
 
1,000 V DC
 
4,000 V DC for 1 min
0.50 mm² conductors
Max. conductor resistance
 
Voltage rating
 
Test voltage
 
38.60 Ω/km at 20°C
 
600 V DC
 
3,000 V DC for 1 min
Min. insulation resistance
Core – Core
Core – Screen
Screen – Screen
 
> 1.00 GΩ/km
> 500 MΩ/km
> 10 MΩ/km
In compliance with CE, UK CA, UK NI, RoHS, LVD

Call us

(858) 454-4044

Address

7416 Cabrillo Avenue, La Jolla, CA  92037, United States