Power/signal cable – Type 5071/B
Power/signal cable – Type 5071/B
Construction characteristics
Conductor |
7 x 0.50 mm² bare copper conductor insulated with XLPE compound (IEC 60228
Class 5). Elements stranded together with Hot Melt Jelly Filler |
Shield |
Tinned copper braid, coverage 85% |
Tape |
Non-woven binder tape |
Outer jacket |
UV resistant polyurethane jacket. Colour black |
Strength member |
Aramid yarn (1 each) |
Flame retardant |
Acc. to CEI EN 60332-1-2, IEC 60332-1-2:2004:07, EN 60332-1-2:2004-11 |
Halogen free |
Acc. to IEC 60754-2, CEI 20-37/2-2, EN 50267-2-2 |
Mechanical characteristics
Diameter |
10.10 mm ±0.30 mm |
Weight in air |
147 kg/km nom |
Weight in seawater |
65 kg/km nom |
Min. bending radius, static |
70 mm |
Min. bending radius, dynamic |
100 mm |
Min. breaking strength |
3.6 kN |
Depth rating |
3,000 m |
Operating temperature range |
-20°C – +80°C |
Electrical characteristics
Operating voltage |
750 V DC |
Test voltage |
3,000 V DC for 1 min |
Conductor resistance |
≤ 39.0 Ω/km |
Insulation resistance |