Power/signal cable – Type 5072CC
| 7 x Conductors | 1.50 mm² (30/0.25 mm) Tinned Copper XLPE insulated, 0.35 mm nom RTI OD: 2.30 mm Colour: BK WH RD GN OR BU BK/WH |
| Lay up | The 6 conductors are twisted around the center conductor Overall helical 12/23µm Ali/PET foil screen, minimum overlap 50% – FOIL OUT OD: 7.0 mm |
| Overall screen | 0.15 mm Tinned Copper Braid Minimum optical coverage 85%, Non-woven Polyester Tissue tape, minimum overlap 50% OD: 7.80 mm |
| Jacket | Polyether Polyurethane, 85 Shore A, Halogen Free, 0.85 mm nom RTI OD: 9.50 mm |
| Max. operating temp Static Dynamic |
+90°C +80°C |
| Cold flex temp | -40°C |
| Depth rating | 3,000 |
| Min. recommended bend radius Static Dynamic |
95 mm 115 mm |
| Nominal weight In air In seawater |
174 kg/km 101 kg/km at SG 1.025 |
| 1.50 mm2 conductors Max. conductor resistance Voltage rating Test voltage |
13.20 Ω/km at 20°C 480 V DC 3,000 V DC for 1 minute |
| Min. insulation resistance Core – Core |
> 100 MΩ/km |
| In compliance with | CE, UK CA, UK NI, RoHS, LVD |